 
		
Benchmark values and test results …
We measured the volume of the fan with a dB meter from a distance of 50cm, as this is the typical distance between fan and user in practice. Measured with the lowest level, 25%, 50%, 75% and 100%, respectively.
| Arctic Summair volume level | |
| lowest level | 35.1dB | 
| 25% | 36.3dB | 
| 50% | 37.3dB | 
| 75% | 38.2dB | 
| 100% | 45.8dB | 
The fan is never really annoying loud, only in the last quarter, it raises, but it is still completely acceptable. The fan noise is a pleasant noise, free of cluttering or grinding noises.
Arctic Summair Light operation …
 
		