Benchmark values and test results …
We measured the volume of the fan with a dB meter from a distance of 50cm, as this is the typical distance between fan and user in practice. Measured with the lowest level, 25%, 50%, 75% and 100%, respectively.
| Arctic Summair volume level | |
| lowest level | 35.1dB |
| 25% | 36.3dB |
| 50% | 37.3dB |
| 75% | 38.2dB |
| 100% | 45.8dB |
The fan is never really annoying loud, only in the last quarter, it raises, but it is still completely acceptable. The fan noise is a pleasant noise, free of cluttering or grinding noises.
Arctic Summair Light operation …